_________________________________________________
3D Codes: |
TraFiC4 |
insensitive to structures smaller than 2mm (this calculation) |
|
TREDI |
CSR part is still in test stage (problems with noise) |
|
||
2D Codes: |
Program by R. Li |
Insensitive to structures smaller than ?mm |
|
||
1D Codes: |
elegant |
overestimates longitudinal field for low frequency components of charge distribution |
|
|
no transverse variation of the longitudinal field |
|
|
no transverse field |
|
|
longitudinal distribution at the time of field calculation is "frozen in time" |
|
|
Fast! |
|
Program by P. Emma |
same as elegant, but even more so |
|
Program by M. Dohlus |
same physics as above, but traces the beam back through several magnets for field calculation |
_________________________________________________
|
|
DE |
DE RMS [%] |
ge [mm] |
3D |
TraFiC4 |
-0.058 |
-0.002 |
1.40 |
|
TREDI |
-0.041 |
0.017* |
2.3** |
|
|
|
|
|
2D |
Program by R. Li |
-0.056 |
-0.006 |
1.32 |
|
|
|
|
|
1D |
elegant |
-0.045 |
-0.0043 |
1.55 |
|
Program by P. Emma |
-0.043 |
-0.004 |
1.52 |
|
Program by M. Dohlus |
-0.045 |
-0.011 |
1.62 |
|
Program by M. Dohlus*** |
-0.043 |
-0.01 |
1.57 |
* |
CSR component only? |
** |
15% charge cut used for emittance calculation |
*** |
CSR term only |